For most wastewater lines, an electromagnetic flow meter is the best choice when the pipe runs full and you can install the meter permanently. If cutting into the pipe is not an option or you need a portable reading, a clamp-on ultrasonic flow meter is a better alternative. In either case, it is best to avoid meters with moving parts, as solids and grease in wastewater can cause them to jam.
Wastewater is hard to measure because it carries solids, grease, air bubbles, and sometimes chemicals. Since wastewater is water that has already been used, a meter that works well on clean water can clog, drift, or fail in this liquid. That is why the right meter depends on what is in your pipe.
You should answer four questions first because they narrow your choice quickly.
In short: use an electromagnetic meter for permanent installation, or a clamp-on ultrasonic meter when you cannot cut the pipe.
An electromagnetic flow meter, also called a mag meter, measures flow by passing liquid through a magnetic field and reading the voltage this creates. It has no moving parts and nothing blocking the pipe, so solids and slurry flow straight through. Slurry is a thick mix of liquid and solids.
This makes it a strong choice for sewage, sludge, and effluent. However, keep two things in mind:
SS Hussain & Sons offers the WFD-DN50 Electromagnetic Flowmeter. It is designed for conductive liquids in 50 mm pipes.
A clamp-on ultrasonic flow meter attaches to the outside of the pipe and sends sound waves through it. Because it stays outside the pipe, you do not need to shut down the system, cut the pipe, or risk leaks.
SS Hussain & Sons has portable, handheld, and wall-mounted ultrasonic flow meters. The TUF-2000 portable meter has these specifications:
However, heavy scale inside the pipe, thick liners, or many air bubbles can weaken the signal. Ask your supplier which model suits dirty liquid and which suits clean liquid.
Avoid turbine and oval gear meters because they have spinning rotors or tight gears and are built for clean fluids. As a result, debris in wastewater can jam them.
The main difference is how you install them. An electromagnetic meter goes inside the pipe line, while a clamp-on ultrasonic meter stays outside the pipe.
| Electromagnetic | Clamp-on ultrasonic | |
| Installation | Inline, pipe is cut | Outside the pipe, no cutting |
| Handles solids | Yes | Depends on the model |
| Pipe must be full | Yes | Yes |
| Best for | Permanent monitoring | Checks, audits, retrofits |
Check these details before you order:
An electromagnetic flow meter is the best choice because it has no moving parts and nothing blocking the pipe, so solids pass through freely.
Yes. A clamp-on ultrasonic flow meter attaches to the outside of the pipe, so you do not need to shut down the system.
Yes, for both meter types. A partly filled pipe gives inaccurate readings.
These meters have spinning rotors or tight gears and are built for clean fluids. Solids and debris in wastewater can jam them.
The TUF-2000 measures pipes from 15 mm to 6000 mm. It handles fluid up to 90 °C, with accuracy of ±1% to ±2% of reading.
Choose an electromagnetic flow meter if the pipe runs full and you can install the meter permanently. If you cannot cut the pipe, choose a clamp-on ultrasonic flow meter instead. In either case, avoid meters with moving parts and check your pipe size, flow range, and temperature before you buy
Need help choosing? Send us your pipe size, fluid type, and flow range. Our team will recommend the right meter. Call or WhatsApp +92 319 3961178, email info@sshussain.com, or request a quote.